SLF / SCALES
SLF Long Cartridge Dust Collector
A central long-cartridge collector with vertical Φ160×2400 mm cartridges in modular housings, 198–3,960 m² of filter area. For high-airflow central systems in tall halls.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

Reference configuration: SLF-11
- Total filtration area
- 198 m²
- Filter element count
- 36
- Filter element dimensions
- Φ160×2400 mm
- Inlet specification
- Φ500 mm
- Solenoid valve count
- 6
- Overall dimensions
- 1550×1950×5350 mm
Values above apply to SLF-11; compare other models below.
Where it fits
- Multi-station welding and cutting
- Body-welding lines, several booths or cutting machines sharing one unit.
- Grinding and shot blasting
- Heavy branches get a pre-separator before the inlet.
- Lithium batteries and powders
- Central collection of fine, light dust.
Features
- Proven filtration performance
- Long cartridges use the stated SCALES filtration arrangement.
- Flexible modular design
- Modular extension and choices of media, hopper, inlet, fan and controller adapt the unit to a plant.
- Easy to service
- The design emphasizes access and serviceability.
How it works
- 1 Inlet
- Dusty air enters the filter chamber from the duct network.
- 2 Filtration
- Dust stays on the outside of the long cartridges; clean air passes into the clean-air plenum.
- 3 Cleaning
- Pulse valves clean row by row; dust falls into the hopper.
- 4 Discharge
- Dust leaves the hopper through a valve or bin.
Maintenance and wear parts
Watch pressure drop and cleaning; when it is abnormal, check airflow and dust load too.
When stopped, check inlet wear and the clean side for dust (a sign of a leaking cartridge).
Long cartridges need handling space along their length.
Wear parts: long cartridges, seals, pulse-valve diaphragms, discharge parts.
FAQ
- Why long cartridges?
- More filter area for the same footprint, suited to high airflow; it needs enough headroom.
- What about expansion?
- Add modules for more filter area, making sure the fan and ducts can take it.
- What do you need for a proposal?
- Number and location of sources, how many run at once, dust type, floor plan and height.
SLF / SPECIFICATIONS
Specifications
Compare models by filter media.
Scroll the table horizontally to compare models; on a phone, open each configuration card.
| Parameter / condition | SLF-11 | SLF-12 | SLF-22 | SLF-32 | SLF-42 | SLF-52 | SLF-62 | SLF-72 | SLF-82 | SLF-92 | SLF-102 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall dimensionsmm | 1550×1950×5350 | 1550×3450×6450 | 3050×3450×6450 | 4550×3450×6450 | 6050×3450×6450 | 7550×3450×6450 | 9050×3450×6450 | 10550×3450×6450 | 12050×3450×6450 | 13550×3450×6450 | 15050×3450×6450 |
| Inlet specificationmm | Φ500 | Φ650 | 2×Φ650 | 3×Φ650 | 4×Φ650 | 5×Φ650 | 6×Φ650 | 7×Φ650 | 8×Φ650 | 9×Φ650 | 10×Φ650 |
| Total filtration aream² | 198 | 396 | 792 | 1188 | 1584 | 1980 | 2376 | 2772 | 3168 | 3564 | 3960 |
| Filter element count | 36 | 72 | 144 | 216 | 288 | 360 | 432 | 504 | 576 | 648 | 720 |
| Filter element dimensionsmm | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 | Φ160×2400 |
| Solenoid valve count | 6 | 6 | 12 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 60 |
SLF-11
- Overall dimensionsmm
- 1550×1950×5350
- Inlet specificationmm
- Φ500
- Total filtration aream²
- 198
- Filter element count
- 36
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 6
SLF-12
- Overall dimensionsmm
- 1550×3450×6450
- Inlet specificationmm
- Φ650
- Total filtration aream²
- 396
- Filter element count
- 72
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 6
SLF-22
- Overall dimensionsmm
- 3050×3450×6450
- Inlet specificationmm
- 2×Φ650
- Total filtration aream²
- 792
- Filter element count
- 144
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 12
SLF-32
- Overall dimensionsmm
- 4550×3450×6450
- Inlet specificationmm
- 3×Φ650
- Total filtration aream²
- 1188
- Filter element count
- 216
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 18
SLF-42
- Overall dimensionsmm
- 6050×3450×6450
- Inlet specificationmm
- 4×Φ650
- Total filtration aream²
- 1584
- Filter element count
- 288
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 24
SLF-52
- Overall dimensionsmm
- 7550×3450×6450
- Inlet specificationmm
- 5×Φ650
- Total filtration aream²
- 1980
- Filter element count
- 360
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 30
SLF-62
- Overall dimensionsmm
- 9050×3450×6450
- Inlet specificationmm
- 6×Φ650
- Total filtration aream²
- 2376
- Filter element count
- 432
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 36
SLF-72
- Overall dimensionsmm
- 10550×3450×6450
- Inlet specificationmm
- 7×Φ650
- Total filtration aream²
- 2772
- Filter element count
- 504
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 42
SLF-82
- Overall dimensionsmm
- 12050×3450×6450
- Inlet specificationmm
- 8×Φ650
- Total filtration aream²
- 3168
- Filter element count
- 576
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 48
SLF-92
- Overall dimensionsmm
- 13550×3450×6450
- Inlet specificationmm
- 9×Φ650
- Total filtration aream²
- 3564
- Filter element count
- 648
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 54
SLF-102
- Overall dimensionsmm
- 15050×3450×6450
- Inlet specificationmm
- 10×Φ650
- Total filtration aream²
- 3960
- Filter element count
- 720
- Filter element dimensionsmm
- Φ160×2400
- Solenoid valve count
- 60
PROCESS & INDUSTRY GUIDANCE
Industries and processes
Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.