SIB / SCALES
SIB Industrial Baghouse Dust Collector
An industrial baghouse with Φ160 long bags (4 m or 6 m), pulse cleaning and modular design. SIB-4-11 to SIB-6-72, 72–1,519 m². For high-airflow, high-loading central collection.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

Where it fits
- Foundries and building materials
- Shake-out, sand handling, crushing, cement mills.
- Chemicals and powders
- Milling, drying, pneumatic conveying, silos.
- Battery materials
- Milling, classifying and packing electrode materials.
Features
- Stable filtration performance
- Long-bag construction organizes area, with media selected for the duty.
- Flexible modular design
- Modules and different media support configuration.
- Easy to service
- The design incorporates serviceability and reliable operation.
How it works
- 1 Inlet
- Dusty gas enters the filter chamber.
- 2 Filtration
- Dust stays on the outside of the long bags, supported by cages.
- 3 Cleaning
- Pulse cleaning drops dust into the hopper.
- 4 Discharge
- Out through a bin or rotary valve.
Maintenance and wear parts
Empty the dust bin at two-thirds full.
Regularly check compressed-air quality, water in the manifold and valve leaks.
When changing bags, check cages, tube-sheet holes, top seals and doors; then watch pressure drop and emissions.
Maintain fan and motor per their own manuals.
FAQ
- 4 m or 6 m bags?
- 6 m gives more area per footprint, but the unit is taller and needs more height to change bags.
- Can bags and cages be changed separately?
- Yes. Check cages for rust and burrs when changing bags and replace them if needed.
- Poor cleaning: where to look first?
- Air pressure and moisture, pulse-valve action, and whether the hopper is full.
Structure drawing

SIB / SPECIFICATIONS
Specifications
Airflow is calculated for the listed media and filtration velocity; system airflow is set by the workstations, hoods and ductwork.
Scroll the table horizontally to compare models; on a phone, open each configuration card.
| Parameter / condition | SIB-4-11 | SIB-4-12 | SIB-4-22 | SIB-4-32 | SIB-4-42 | SIB-4-52 | SIB-4-62 | SIB-4-72 | SIB-6-11 | SIB-6-12 | SIB-6-22 | SIB-6-32 | SIB-6-42 | SIB-6-52 | SIB-6-62 | SIB-6-72 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall dimensionsmm | 1550×1950×7240 | 1550×3450×8450 | 3050×3450×8450 | 4550×3450×8450 | 6050×3450×8450 | 7550×3450×8450 | 9050×3450×8450 | 10550×3450×8450 | 1550×1950×9240 | 1550×3450×10450 | 3050×3450×10450 | 4550×3450×10450 | 6050×3450×10450 | 7550×3450×10450 | 9050×3450×10450 | 10550×3450×10450 |
| Inlet specificationmm | Φ300–Φ350 | Φ400–Φ450 | 2×(Φ400–Φ450) | 3×(Φ400–Φ450) | 4×(Φ400–Φ450) | 5×(Φ400–Φ450) | 6×(Φ400–Φ450) | 7×(Φ400–Φ450) | Φ350–Φ400 | Φ500–Φ550 | 2×(Φ500–Φ550) | 3×(Φ500–Φ550) | 4×(Φ500–Φ550) | 5×(Φ500–Φ550) | 6×(Φ500–Φ550) | 7×(Φ500–Φ550) |
| Total filtration aream² | 72 | 144 | 288 | 432 | 576 | 720 | 864 | 1008 | 108 | 217 | 434 | 651 | 868 | 1085 | 1302 | 1519 |
| Filter element count | 36 | 72 | 144 | 216 | 288 | 360 | 432 | 504 | 36 | 72 | 144 | 216 | 288 | 360 | 432 | 504 |
| Filter element dimensionsmm | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×4000 | Φ160×6000 | Φ160×6000 | Φ160×6000 | Φ160×6000 | Φ160×6000 | Φ160×6000 | Φ160×6000 | Φ160×6000 |
| Pulse valve count | 6 | 6 | 12 | 18 | 24 | 30 | 36 | 42 | 6 | 6 | 12 | 18 | 24 | 30 | 36 | 42 |
SIB-4-11
- Overall dimensionsmm
- 1550×1950×7240
- Inlet specificationmm
- Φ300–Φ350
- Total filtration aream²
- 72
- Filter element count
- 36
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 6
SIB-4-12
- Overall dimensionsmm
- 1550×3450×8450
- Inlet specificationmm
- Φ400–Φ450
- Total filtration aream²
- 144
- Filter element count
- 72
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 6
SIB-4-22
- Overall dimensionsmm
- 3050×3450×8450
- Inlet specificationmm
- 2×(Φ400–Φ450)
- Total filtration aream²
- 288
- Filter element count
- 144
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 12
SIB-4-32
- Overall dimensionsmm
- 4550×3450×8450
- Inlet specificationmm
- 3×(Φ400–Φ450)
- Total filtration aream²
- 432
- Filter element count
- 216
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 18
SIB-4-42
- Overall dimensionsmm
- 6050×3450×8450
- Inlet specificationmm
- 4×(Φ400–Φ450)
- Total filtration aream²
- 576
- Filter element count
- 288
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 24
SIB-4-52
- Overall dimensionsmm
- 7550×3450×8450
- Inlet specificationmm
- 5×(Φ400–Φ450)
- Total filtration aream²
- 720
- Filter element count
- 360
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 30
SIB-4-62
- Overall dimensionsmm
- 9050×3450×8450
- Inlet specificationmm
- 6×(Φ400–Φ450)
- Total filtration aream²
- 864
- Filter element count
- 432
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 36
SIB-4-72
- Overall dimensionsmm
- 10550×3450×8450
- Inlet specificationmm
- 7×(Φ400–Φ450)
- Total filtration aream²
- 1008
- Filter element count
- 504
- Filter element dimensionsmm
- Φ160×4000
- Pulse valve count
- 42
SIB-6-11
- Overall dimensionsmm
- 1550×1950×9240
- Inlet specificationmm
- Φ350–Φ400
- Total filtration aream²
- 108
- Filter element count
- 36
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 6
SIB-6-12
- Overall dimensionsmm
- 1550×3450×10450
- Inlet specificationmm
- Φ500–Φ550
- Total filtration aream²
- 217
- Filter element count
- 72
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 6
SIB-6-22
- Overall dimensionsmm
- 3050×3450×10450
- Inlet specificationmm
- 2×(Φ500–Φ550)
- Total filtration aream²
- 434
- Filter element count
- 144
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 12
SIB-6-32
- Overall dimensionsmm
- 4550×3450×10450
- Inlet specificationmm
- 3×(Φ500–Φ550)
- Total filtration aream²
- 651
- Filter element count
- 216
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 18
SIB-6-42
- Overall dimensionsmm
- 6050×3450×10450
- Inlet specificationmm
- 4×(Φ500–Φ550)
- Total filtration aream²
- 868
- Filter element count
- 288
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 24
SIB-6-52
- Overall dimensionsmm
- 7550×3450×10450
- Inlet specificationmm
- 5×(Φ500–Φ550)
- Total filtration aream²
- 1085
- Filter element count
- 360
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 30
SIB-6-62
- Overall dimensionsmm
- 9050×3450×10450
- Inlet specificationmm
- 6×(Φ500–Φ550)
- Total filtration aream²
- 1302
- Filter element count
- 432
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 36
SIB-6-72
- Overall dimensionsmm
- 10550×3450×10450
- Inlet specificationmm
- 7×(Φ500–Φ550)
- Total filtration aream²
- 1519
- Filter element count
- 504
- Filter element dimensionsmm
- Φ160×6000
- Pulse valve count
- 42
PROCESS & INDUSTRY GUIDANCE
Industries and processes
Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.