SMB / SCALES
SMB Trolley-Cleaning Baghouse Dust Collector
A reverse-air trolley baghouse: horizontal flat bags cleaned row by row by a travelling trolley, with no compressed air and no stopping. SMB-7-20-1 to SMB-7-20-11, 210–2,310 m². For hot gas from aluminium and foundry work, and quarry dust.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

Where it fits
- Aluminium and foundry melting
- Cooled hot gas with continuous cleaning.
- Quarrying and minerals
- Ambient dust, continuous duty.
- Sites without compressed air
- Its own reverse-air fan, no air supply needed.
Features
- Stable reverse-air cleaning
- Travelling reverse-air cleaning, horizontal flat bags and downflow align cleaning with falling dust.
- Flexible modular design
- Modules and bag media adapt the arrangement.
- Compact construction
- Flat bags and modules organize the installation space.
- Easy to service
- Horizontal insertion assists bag installation, replacement and inspection.
How it works

SMB series structure: travelling reverse-air trolley with its fan, bag section and access platform.
How to read it
- The cleaning fan and its valve are at the top.
- The travelling cleaning assembly and nozzles serve the bag section.
- The hopper sits below; a platform and ladder provide maintenance access.
- 1 Inlet
- Dusty air enters from the top.
- 2 Filtration
- Horizontal 370×2200 mm flat bags capture the dust.
- 3 Cleaning
- The trolley travels along the rows and its fan blows each row in reverse to release the dust.
- 4 Discharge
- Dust leaves through the hopper.
Maintenance and wear parts
Every 2,000 hours per the manual: bags and clean side, reverse-air fan, cleaning valve, metal bellows, nozzle joints, reverse-air chamber.
Also check trolley wheels, drive and return gear, chains and ropes for wear, looseness and tension.
Isolate before dismantling.
FAQ
- Is the reverse-air fan the main fan?
- No. The reverse-air fan only cleans; the system main fan is separate.
- What temperature?
- It depends on the bag material; cool the gas below its rating first.
- Versus SMC, what to ask first?
- Is reliable compressed air available, is the gas hot, and is continuous cleaning needed?
SMB / SPECIFICATIONS
Specifications
Airflow is calculated for the listed media and filtration velocity; system airflow is set by the workstations, hoods and ductwork.
Scroll the table horizontally to compare models; on a phone, open each configuration card.
| Parameter / condition | SMB-7-20-1 | SMB-7-20-2 | SMB-7-20-3 | SMB-7-20-4 | SMB-7-20-5 | SMB-7-20-6 | SMB-7-20-7 | SMB-7-20-8 | SMB-7-20-9 | SMB-7-20-10 | SMB-7-20-11 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall dimensionsmm | 1350×4200×7100 | 3700×4200×7500 | 4800×4200×8400 | 6000×4200×8800 | 7100×4200×9700 | 7100×4200×10000 | 9400×4200×10500 | 10600×4200×11000 | 11700×4200×11300 | 12900×4200×11700 | 14000×4200×12200 |
| Filter element count | 140 | 280 | 420 | 560 | 700 | 840 | 980 | 1120 | 1260 | 1400 | 1540 |
| Total filtration aream² | 210 | 420 | 630 | 840 | 1050 | 1260 | 1470 | 1680 | 1890 | 2100 | 2310 |
| Filter element dimensionsmm | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 | 370×2200 |
SMB-7-20-1
- Overall dimensionsmm
- 1350×4200×7100
- Filter element count
- 140
- Total filtration aream²
- 210
- Filter element dimensionsmm
- 370×2200
SMB-7-20-2
- Overall dimensionsmm
- 3700×4200×7500
- Filter element count
- 280
- Total filtration aream²
- 420
- Filter element dimensionsmm
- 370×2200
SMB-7-20-3
- Overall dimensionsmm
- 4800×4200×8400
- Filter element count
- 420
- Total filtration aream²
- 630
- Filter element dimensionsmm
- 370×2200
SMB-7-20-4
- Overall dimensionsmm
- 6000×4200×8800
- Filter element count
- 560
- Total filtration aream²
- 840
- Filter element dimensionsmm
- 370×2200
SMB-7-20-5
- Overall dimensionsmm
- 7100×4200×9700
- Filter element count
- 700
- Total filtration aream²
- 1050
- Filter element dimensionsmm
- 370×2200
SMB-7-20-6
- Overall dimensionsmm
- 7100×4200×10000
- Filter element count
- 840
- Total filtration aream²
- 1260
- Filter element dimensionsmm
- 370×2200
SMB-7-20-7
- Overall dimensionsmm
- 9400×4200×10500
- Filter element count
- 980
- Total filtration aream²
- 1470
- Filter element dimensionsmm
- 370×2200
SMB-7-20-8
- Overall dimensionsmm
- 10600×4200×11000
- Filter element count
- 1120
- Total filtration aream²
- 1680
- Filter element dimensionsmm
- 370×2200
SMB-7-20-9
- Overall dimensionsmm
- 11700×4200×11300
- Filter element count
- 1260
- Total filtration aream²
- 1890
- Filter element dimensionsmm
- 370×2200
SMB-7-20-10
- Overall dimensionsmm
- 12900×4200×11700
- Filter element count
- 1400
- Total filtration aream²
- 2100
- Filter element dimensionsmm
- 370×2200
SMB-7-20-11
- Overall dimensionsmm
- 14000×4200×12200
- Filter element count
- 1540
- Total filtration aream²
- 2310
- Filter element dimensionsmm
- 370×2200
PROCESS & INDUSTRY GUIDANCE
Industries and processes
Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.