SCW / SCALES
SCW Workroom Cartridge Dust Collector
A grinding booth with built-in cartridge filtration: large or irregular parts are ground inside and the dust is extracted and filtered on the spot. SCW-4-1 to SCW-8-2, combined to suit part length.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

Where it fits
- Large and irregular parts
- Construction-machinery structures, castings and weldments that hoods cannot reach.
- Several operators
- Booths combine by length so several people can work at once.
- Grinding, polishing, cleaning
- Steel, composites and woodworking.
Features
- Effective, reliable cleaning
- Cleaning uses a large air receiver and supports the specified high/low pressure pulse arrangements.
- Flexible modular design
- A three-dimensional modular system and different media can be configured to the order.
- Proven filtration design
- Mature media and construction balance filtration, maintenance and cost.
- Easy to service
- The design incorporates serviceability and reliable operation.
How it works
- 1 Intake
- Air is drawn to the back wall, carrying grinding dust away from the opening.
- 2 Filtration
- Dust is held on the outside of Φ325×1000 cartridges.
- 3 Cleaning
- Pulse valves knock the dust down into the collection point.
- 4 Discharge
- Clean air is discharged.
Maintenance and wear parts
Each shift, clear material that blocks airflow and keep openings clear.
Check pressure drop and cleaning; inspect dust drawers or containers and door seals.
Wear parts: cartridges, door seals, pulse-valve diaphragms, container seals.
FAQ
- How is it different from a central cartridge system?
- SCW combines booth and collector with no duct network, suited to large-part grinding; scattered stations suit a central cartridge system better.
- Is one module enough?
- It depends on part length and number of operators: SCW-4-1 to SCW-8-2, 120–480 m² with nano-membrane.
- What do you need for a quote?
- Largest part size, grinding method, number of operators, material, and the space available.
Structure drawing

SCW / SPECIFICATIONS
Specifications
Airflow is calculated for the listed media and filtration velocity; system airflow is set by the workstations, hoods and ductwork.
Airflow is calculated from filter area at filtration velocities of 0.85–1.2 m/min.
- Nanomembrane media at a filtration velocity of 0.85 m/min.
- Nanomembrane media at a filtration velocity of 1.2 m/min.
- Polyester-membrane media at a filtration velocity of 0.85 m/min.
- Polyester-membrane media at a filtration velocity of 1.2 m/min.
- At 1.5 m from the equipment (measuring distance).
Scroll the table horizontally to compare models; on a phone, open each configuration card.
| Parameter / condition | SCW-4-1 | SCW-8-1 | SCW-12-1 | SCW-8-2 |
|---|---|---|---|---|
| Power supply | AC 380 V / 3 Ph / 50 Hz | AC 380 V / 3 Ph / 50 Hz | AC 380 V / 3 Ph / 50 Hz | AC 380 V / 3 Ph / 50 Hz |
| Filtration area · nanomembranem² | 120 | 240 | 360 | 480 |
| Filtration area · polyester membranem² | 60 | 120 | 180 | 240 |
| Filter element dimensionsmm | Φ325×1000 | Φ325×1000 | Φ325×1000 | Φ325×1000 |
| Filter element count | 4 | 8 | 12 | 16 |
| Initial differential pressurePa | 200–260 | 200–260 | 200–260 | 200–260 |
| Airflow · nanomembrane · 0.85 m/minm³/h | 6120 | 12240 | 18360 | 24480 |
| Airflow · nanomembrane · 1.2 m/minm³/h | 8640 | 17280 | 25920 | 34560 |
| Airflow · polyester membrane · 0.85 m/minm³/h | 3060 | 6120 | 9180 | 12240 |
| Airflow · polyester membrane · 1.2 m/minm³/h | 4320 | 8640 | 12960 | 17280 |
| Fan power · nanomembranekW | 4–5.5 | 7.5–11 | 4+7.5 | 2×7.5 |
| Fan power · polyester membranekW | 3–4 | 4–5.5 | 3+4 | 2×4 |
| Fan static pressurePa | 1500 | 1500 | 1500 | 1500 |
| Noise (1.5 m from equipment)dB(A) | 80–85 (at 1.5 m from the equipment) dB(A) | 80–85 (at 1.5 m from the equipment) dB(A) | 80–85 (at 1.5 m from the equipment) dB(A) | 80–85 (at 1.5 m from the equipment) dB(A) |
| Overall dimensionsmm | 1000×1150×2720 | 2000×1150×2720 | 3000×1150×2720 | 4000×1150×2720 |
SCW-4-1
- Power supply
- AC 380 V / 3 Ph / 50 Hz
- Filtration area · nanomembranem²
- 120
- Filtration area · polyester membranem²
- 60
- Filter element dimensionsmm
- Φ325×1000
- Filter element count
- 4
- Initial differential pressurePa
- 200–260
- Airflow · nanomembrane · 0.85 m/minm³/h
- 6120Nanomembrane media at a filtration velocity of 0.85 m/min.
- Airflow · nanomembrane · 1.2 m/minm³/h
- 8640Nanomembrane media at a filtration velocity of 1.2 m/min.
- Airflow · polyester membrane · 0.85 m/minm³/h
- 3060Polyester-membrane media at a filtration velocity of 0.85 m/min.
- Airflow · polyester membrane · 1.2 m/minm³/h
- 4320Polyester-membrane media at a filtration velocity of 1.2 m/min.
- Fan power · nanomembranekW
- 4–5.5
- Fan power · polyester membranekW
- 3–4
- Fan static pressurePa
- 1500
- Noise (1.5 m from equipment)dB(A)
- 80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
- Overall dimensionsmm
- 1000×1150×2720
SCW-8-1
- Power supply
- AC 380 V / 3 Ph / 50 Hz
- Filtration area · nanomembranem²
- 240
- Filtration area · polyester membranem²
- 120
- Filter element dimensionsmm
- Φ325×1000
- Filter element count
- 8
- Initial differential pressurePa
- 200–260
- Airflow · nanomembrane · 0.85 m/minm³/h
- 12240Nanomembrane media at a filtration velocity of 0.85 m/min.
- Airflow · nanomembrane · 1.2 m/minm³/h
- 17280Nanomembrane media at a filtration velocity of 1.2 m/min.
- Airflow · polyester membrane · 0.85 m/minm³/h
- 6120Polyester-membrane media at a filtration velocity of 0.85 m/min.
- Airflow · polyester membrane · 1.2 m/minm³/h
- 8640Polyester-membrane media at a filtration velocity of 1.2 m/min.
- Fan power · nanomembranekW
- 7.5–11
- Fan power · polyester membranekW
- 4–5.5
- Fan static pressurePa
- 1500
- Noise (1.5 m from equipment)dB(A)
- 80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
- Overall dimensionsmm
- 2000×1150×2720
SCW-12-1
- Power supply
- AC 380 V / 3 Ph / 50 Hz
- Filtration area · nanomembranem²
- 360
- Filtration area · polyester membranem²
- 180
- Filter element dimensionsmm
- Φ325×1000
- Filter element count
- 12
- Initial differential pressurePa
- 200–260
- Airflow · nanomembrane · 0.85 m/minm³/h
- 18360Nanomembrane media at a filtration velocity of 0.85 m/min.
- Airflow · nanomembrane · 1.2 m/minm³/h
- 25920Nanomembrane media at a filtration velocity of 1.2 m/min.
- Airflow · polyester membrane · 0.85 m/minm³/h
- 9180Polyester-membrane media at a filtration velocity of 0.85 m/min.
- Airflow · polyester membrane · 1.2 m/minm³/h
- 12960Polyester-membrane media at a filtration velocity of 1.2 m/min.
- Fan power · nanomembranekW
- 4+7.5
- Fan power · polyester membranekW
- 3+4
- Fan static pressurePa
- 1500
- Noise (1.5 m from equipment)dB(A)
- 80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
- Overall dimensionsmm
- 3000×1150×2720
SCW-8-2
- Power supply
- AC 380 V / 3 Ph / 50 Hz
- Filtration area · nanomembranem²
- 480
- Filtration area · polyester membranem²
- 240
- Filter element dimensionsmm
- Φ325×1000
- Filter element count
- 16
- Initial differential pressurePa
- 200–260
- Airflow · nanomembrane · 0.85 m/minm³/h
- 24480Nanomembrane media at a filtration velocity of 0.85 m/min.
- Airflow · nanomembrane · 1.2 m/minm³/h
- 34560Nanomembrane media at a filtration velocity of 1.2 m/min.
- Airflow · polyester membrane · 0.85 m/minm³/h
- 12240Polyester-membrane media at a filtration velocity of 0.85 m/min.
- Airflow · polyester membrane · 1.2 m/minm³/h
- 17280Polyester-membrane media at a filtration velocity of 1.2 m/min.
- Fan power · nanomembranekW
- 2×7.5
- Fan power · polyester membranekW
- 2×4
- Fan static pressurePa
- 1500
- Noise (1.5 m from equipment)dB(A)
- 80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
- Overall dimensionsmm
- 4000×1150×2720
PROCESS & INDUSTRY GUIDANCE
Industries and processes
Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.