The Measure of Clean Air.

SCU / SCALES

SCU Integrated Cartridge Dust Collector

Built for laser cutting, plasma cutting and welding. Fan, cartridges, pulse cleaning and dust drawer come in one cabinet. Connect power and compressed air, and it runs.

SCU series product image
SCU Integrated Cartridge Dust Collector

Reference configuration: SCU-4

Airflow · nanomembrane · 0.85 m/min
6120 m³/h
Filtration area · nanomembrane
120 m²
Fan static pressure
2500 Pa
Fan power · nanomembrane
5.5–7.5 kW
Filter element dimensions
Φ325×1000 mm
Overall dimensions
1050×1150×2720 mm

Values above apply to SCU-4; compare other models below.

Where it fits

Laser cutting tables
Zoned downdraft extraction goes straight into the unit. No separate collector room is needed.
Plasma cutting
A spark-arrestor inlet stops sparks before they reach the cartridges.
Robotic welding cells and fixed booths
One unit per cell keeps ducts short and pressure loss low.

Features

Ready to run
Pulse cleaning, fan start/stop control, oil-water separator and inlet baffle are factory-fitted. Only power and compressed air are needed on site.
Vertical cartridges
Dust cannot settle on top of the cartridge, so cleaning is more thorough and changes are easier.
Reliable cleaning
Pulse valves work from 0.2 to 0.6 MPa and are rated for up to one million cycles.
Choice of media
Nano-membrane or polyester membrane. Filter area and airflow change with the media; both are listed in the specifications.

How it works

Fume enters from the capture point and passes through the media to the clean-air side. Pulse cleaning releases dust from the outside for collection. The catalogue lists fan start/stop control, an oil/water separator and an inlet flow-distribution hood.

SCU source cutaway showing a vertical cartridge, upper fan section, side inlet and lower dust drawer.
SCU integrated collector internal structure

SCU series structure: cartridges, access doors, inlet hood and dust drawer.

How to read it

  • Cartridge access door / vertical cartridge: the cartridge sits in the lower filtration section behind the access door.
  • Fan service area / outlet panel: above the filtration section, identifying the fan service and clean-air outlet.
  • Inlet hood / dust drawer: the inlet hood is on the side and the dust drawer is at the base.
  • Electrical control box: identifies start/stop, cleaning controls and the site electrical interface.
1 Inlet
Dusty air enters through the inlet hood and is spread by the baffle.
2 Filtration
Fume collects on the outside of the cartridges; clean air passes into the core.
3 Discharge
The fan discharges clean air at the top.
4 Cleaning
Pulse valves fire compressed air into each cartridge in turn and knock the dust off.
5 Dust collection
Dust drops into the drawer at the base for emptying.

Maintenance and wear parts

Start maintenance with capture flow, pressure trend, pulse operation, air quality and dust collection. Establish a clean-filter baseline and keep the duty with each reading. At replacement, inspect seals, retainers, doors and the clean side, then recheck the same station combination.

Key wear parts include cartridges, seals, valve diaphragms and air hoses.

Service media, air and collection separately. Inspect element/seal integrity, air preparation/leaks/pulses and dust discharge. Contain removed media, clean sealing surfaces and restore doors.

Recheck the same stations and valves; persistent low flow after replacement also calls for duct/fan/interface diagnosis.

Capture, pressure and cleaning
Record hood condition, differential-pressure trend, cleaning action and discharge together. Investigate the source and system before servicing individual components under the equipment instructions.

FAQ

Extraction arm or cutting table?
SCU connects to fixed points: cutting tables, booths and robot cells. For welding that moves with the workpiece, choose the SCS mobile extractor.
Which filter media?
For welding and laser fume, choose nano-membrane: it gives twice the filter area of polyester membrane. Polyester membrane suits general dry dust.
When should cartridges be changed?
When pressure drop stays high after cleaning, airflow falls, or dust is visible at the outlet. Change the full set.
What should be ready on site?
A level base, 380 V supply, clean dry compressed air at 0.2–0.6 MPa, and the inlet duct connection.

SCU / SPECIFICATIONS

Specifications

Discuss SCU configurations

Compare models by filter media.

Airflow is calculated from filter area at filtration velocities of 0.85–1.2 m/min.

  • Nanomembrane media at a filtration velocity of 0.85 m/min.
  • Nanomembrane media at a filtration velocity of 1.2 m/min.
  • Polyester-membrane media at a filtration velocity of 0.85 m/min.
  • Polyester-membrane media at a filtration velocity of 1.2 m/min.
  • At 1.5 m from the equipment (measuring distance).

Scroll the table horizontally to compare models; on a phone, open each configuration card.

SCUmodel comparison
Parameter / conditionSCU-4SCU-6SCU-9SCU-12
Power supply380 V / 3 Ph / 50 Hz380 V / 3 Ph / 50 Hz380 V / 3 Ph / 50 Hz380 V / 3 Ph / 50 Hz
Filtration area · nanomembranem²120180270360
Filtration area · polyester membranem²6090135180
Filter element dimensionsmmΦ325×1000Φ325×1000Φ325×1000Φ325×1000
Filter element count46912
Initial differential pressurePa200–260200–260200–260200–260
Airflow · nanomembrane · 0.85 m/minm³/h612091801377018360
Airflow · nanomembrane · 1.2 m/minm³/h8640129601944025920
Airflow · polyester membrane · 0.85 m/minm³/h3060459068859180
Airflow · polyester membrane · 1.2 m/minm³/h43206480972012960
Fan power · nanomembranekW5.5–7.57.5–1111–1515–18.5
Fan power · polyester membranekW3–44–5.55.5–7.57.5–11
Fan static pressurePa2500250025002500
Noise (1.5 m from equipment)dB(A)80–85 (at 1.5 m from the equipment) dB(A)80–85 (at 1.5 m from the equipment) dB(A)80–85 (at 1.5 m from the equipment) dB(A)80–85 (at 1.5 m from the equipment) dB(A)
Overall dimensionsmm1050×1150×27201550×1150×28201550×1525×30502050×1525×3050
Gross weight · nanomembranekg680102015302040
Gross weight · polyester membranekg64096014401920
SCU-4
Power supply
380 V / 3 Ph / 50 Hz
Filtration area · nanomembranem²
120
Filtration area · polyester membranem²
60
Filter element dimensionsmm
Φ325×1000
Filter element count
4
Initial differential pressurePa
200–260
Airflow · nanomembrane · 0.85 m/minm³/h
6120Nanomembrane media at a filtration velocity of 0.85 m/min.
Airflow · nanomembrane · 1.2 m/minm³/h
8640Nanomembrane media at a filtration velocity of 1.2 m/min.
Airflow · polyester membrane · 0.85 m/minm³/h
3060Polyester-membrane media at a filtration velocity of 0.85 m/min.
Airflow · polyester membrane · 1.2 m/minm³/h
4320Polyester-membrane media at a filtration velocity of 1.2 m/min.
Fan power · nanomembranekW
5.5–7.5
Fan power · polyester membranekW
3–4
Fan static pressurePa
2500
Noise (1.5 m from equipment)dB(A)
80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
Overall dimensionsmm
1050×1150×2720
Gross weight · nanomembranekg
680
Gross weight · polyester membranekg
640
Enquire about this model
SCU-6
Power supply
380 V / 3 Ph / 50 Hz
Filtration area · nanomembranem²
180
Filtration area · polyester membranem²
90
Filter element dimensionsmm
Φ325×1000
Filter element count
6
Initial differential pressurePa
200–260
Airflow · nanomembrane · 0.85 m/minm³/h
9180Nanomembrane media at a filtration velocity of 0.85 m/min.
Airflow · nanomembrane · 1.2 m/minm³/h
12960Nanomembrane media at a filtration velocity of 1.2 m/min.
Airflow · polyester membrane · 0.85 m/minm³/h
4590Polyester-membrane media at a filtration velocity of 0.85 m/min.
Airflow · polyester membrane · 1.2 m/minm³/h
6480Polyester-membrane media at a filtration velocity of 1.2 m/min.
Fan power · nanomembranekW
7.5–11
Fan power · polyester membranekW
4–5.5
Fan static pressurePa
2500
Noise (1.5 m from equipment)dB(A)
80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
Overall dimensionsmm
1550×1150×2820
Gross weight · nanomembranekg
1020
Gross weight · polyester membranekg
960
Enquire about this model
SCU-9
Power supply
380 V / 3 Ph / 50 Hz
Filtration area · nanomembranem²
270
Filtration area · polyester membranem²
135
Filter element dimensionsmm
Φ325×1000
Filter element count
9
Initial differential pressurePa
200–260
Airflow · nanomembrane · 0.85 m/minm³/h
13770Nanomembrane media at a filtration velocity of 0.85 m/min.
Airflow · nanomembrane · 1.2 m/minm³/h
19440Nanomembrane media at a filtration velocity of 1.2 m/min.
Airflow · polyester membrane · 0.85 m/minm³/h
6885Polyester-membrane media at a filtration velocity of 0.85 m/min.
Airflow · polyester membrane · 1.2 m/minm³/h
9720Polyester-membrane media at a filtration velocity of 1.2 m/min.
Fan power · nanomembranekW
11–15
Fan power · polyester membranekW
5.5–7.5
Fan static pressurePa
2500
Noise (1.5 m from equipment)dB(A)
80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
Overall dimensionsmm
1550×1525×3050
Gross weight · nanomembranekg
1530
Gross weight · polyester membranekg
1440
Enquire about this model
SCU-12
Power supply
380 V / 3 Ph / 50 Hz
Filtration area · nanomembranem²
360
Filtration area · polyester membranem²
180
Filter element dimensionsmm
Φ325×1000
Filter element count
12
Initial differential pressurePa
200–260
Airflow · nanomembrane · 0.85 m/minm³/h
18360Nanomembrane media at a filtration velocity of 0.85 m/min.
Airflow · nanomembrane · 1.2 m/minm³/h
25920Nanomembrane media at a filtration velocity of 1.2 m/min.
Airflow · polyester membrane · 0.85 m/minm³/h
9180Polyester-membrane media at a filtration velocity of 0.85 m/min.
Airflow · polyester membrane · 1.2 m/minm³/h
12960Polyester-membrane media at a filtration velocity of 1.2 m/min.
Fan power · nanomembranekW
15–18.5
Fan power · polyester membranekW
7.5–11
Fan static pressurePa
2500
Noise (1.5 m from equipment)dB(A)
80–85 (at 1.5 m from the equipment) dB(A)At 1.5 m from the equipment (measuring distance).
Overall dimensionsmm
2050×1525×3050
Gross weight · nanomembranekg
2040
Gross weight · polyester membranekg
1920
Enquire about this model