SCU SERIES / CARTRIDGE DUST COLLECTION
SCU-4 Cartridge Dust Collector
The four-cartridge model of the SCU series, for welding and cutting fume. Choose nano-membrane or polyester-membrane media; filter area, airflow and fan power depend on the media.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

- Cartridges
- 4
- Cartridge dimensions
- Φ325×1000 mm
- Power supply
- 380 V / 3 Ph / 50 Hz
PRODUCT CONFIGURATION
Two media options.
The two media differ in filter area, reference airflow, fan power and gross weight. For fine, sticky welding fume, nano-membrane media is the first choice.
Nano-coated media
- Filter area
- 120 m²
- Reference airflow
- 6120–8640 m³/h
- Fan power
- 5.5–7.5 kW
- Gross weight
- 680 kg
Airflow calculated at a filtration velocity of 0.85–1.2 m/min.
Polyester-coated media
- Filter area
- 60 m²
- Reference airflow
- 3060–4320 m³/h
- Fan power
- 3–4 kW
- Gross weight
- 640 kg
Airflow calculated at a filtration velocity of 0.85–1.2 m/min.
SPECIFICATIONS
Technical data
Media-dependent values first, then supply, pressure, dimensions and noise.
On a phone, swipe inside the table to see every column.
| Parameter | Value | Condition |
|---|---|---|
| Power supply | 380 V / 3 Ph / 50 Hz | — |
| Filtration area · nanomembranem² | 120 | — |
| Filtration area · polyester membranem² | 60 | — |
| Filter element dimensionsmm | Φ325×1000 | — |
| Filter element count | 4 | — |
| Initial differential pressurePa | 200–260 | — |
| Airflow · nanomembrane · 0.85 m/minm³/h | 6120 | Nanomembrane media at a filtration velocity of 0.85 m/min. |
| Airflow · nanomembrane · 1.2 m/minm³/h | 8640 | Nanomembrane media at a filtration velocity of 1.2 m/min. |
| Airflow · polyester membrane · 0.85 m/minm³/h | 3060 | Polyester-membrane media at a filtration velocity of 0.85 m/min. |
| Airflow · polyester membrane · 1.2 m/minm³/h | 4320 | Polyester-membrane media at a filtration velocity of 1.2 m/min. |
| Fan power · nanomembranekW | 5.5–7.5 | — |
| Fan power · polyester membranekW | 3–4 | — |
| Fan static pressurePa | 2500 | — |
| Noise (1.5 m from equipment)dB(A) | 80–85 (at 1.5 m from the equipment) dB(A) | At 1.5 m from the equipment (measuring distance). |
| Overall dimensionsmm | 1050×1150×2720 | — |
| Gross weight · nanomembranekg | 680 | — |
| Gross weight · polyester membranekg | 640 | — |
APPLICATIONS
Applications
The SCU series is used for welding, laser cutting and plasma cutting. To recommend the right configuration, please tell us the following.
- Welding fume
- Welding method and material, workstation layout, simultaneous operation, hood type and capture distance.
- Laser cutting
- Cutting material, machine work area and extraction zones, operating cycle, existing ductwork and spark conditions.
- Plasma cutting
- Material and cutting conditions, fume-generation points, table extraction arrangement, heat and spark conditions.
Family construction and control details
Main construction and features of the SCU series.
Vertical cartridge arrangement
Cartridges stand vertically and slide out through the access door, so there is no need to climb on top of the unit.
Pulse cleaning
Compressed-air pulses blow dust off the cartridges into the dust drawer, cleaning automatically as the pressure drop rises.
Control and inlet components
Fan start/stop control, an oil/water separator that protects the pulse-air supply, and an inlet hood that spreads the dusty air evenly across the cartridges.
SERVICE & DOCUMENTATION
Maintenance and technical documentation
Each unit comes with a configuration sheet, a general arrangement drawing and operation and maintenance documents. For maintenance or spares, send the nameplate details and photos of the parts.
- Model configuration sheet
- Media, cartridge specification, fan, electrical supply and supplied accessories.
- General arrangement and installation drawing
- Inlet and outlet, access doors, cartridge removal direction and dust-handling space.
- Operation and maintenance documentation
- Cleaning settings, compressed-air requirements, routine checks and wear parts.
Drawings and documents
Dimensions, connections and installation requirements are shown on the general arrangement drawing supplied with the order.
When requesting documents, state the model and media, and whether you need installation, operation, maintenance or spare-parts information.