Old system not capturing, costing too much power, eating filters? Find the cause first, then decide whether to repair, modify or replace.
Submit a service request01
When a retrofit is needed
Many systems lose performance after a few years: the process changed, stations were added, ducts filled with dust, or the media no longer suits the duty. Find the real problem before changing anything, or new equipment may not help. SCALES works in seven steps and compares before and after under the same conditions.
- Fume and dust escape at the stations and haze hangs in the hall.
- High pressure drop, low airflow, ever more frequent filter changes.
- High fan current and power bills.
- Expansion has added stations or machines.
- The process changed: material, welding method or coolant.
- New environmental or safety rules the system cannot meet.
- Equipment is ageing, corroded or leaking.
02
Seven steps
| Step | What happens | Result |
|---|---|---|
| 1 Baseline survey | Under normal production, measure hood velocity, branch airflow, system pressure, pressure drop and fan current; take photos | Baseline data sheet |
| 2 Find the bottleneck | Check hoods, ducts, collector, fan and controls in turn: hood too far away? Ducts too restrictive? Wrong media? Fan too small? Poor cleaning control? | Problem list and root causes |
| 3 Safety and interfaces | Combustible dust, sparks, heat, recirculation; structure, space, power and shutdown time | Scope and safety requirements |
| 4 Compare options | Repair (new media, fix leaks), partial retrofit (new hoods, rebalanced ducts, VFD) or replacement, compared on results, cost and downtime | Options table for your decision |
| 5 Plan the work | Shutdown window, sequence, safety measures, spares | Work plan |
| 6 Check | Measure the same points under the same production conditions | Before-and-after comparison |
| 7 Update records | Update drawings, equipment list and maintenance plan; train staff if needed | New drawings and maintenance documents |
03
Common retrofit measures
- Improve capture
- Moving the hood closer to the source or adding enclosure often works better than more airflow.
- Rework the ducts
- Remove unnecessary bends, re-route branches and add dampers to balance them.
- Change the media
- A better-suited membrane or antistatic media lowers resistance and lasts longer.
- Add VFD and pressure control
- Run airflow to demand and clean on pressure drop to cut energy use. SVB-T comes with VFD control and pressure feedback.
- Add modules
- Modular units such as SHF, SLF, SMC and SIB take extra modules for more filter capacity.
- Replace the unit
- When the unit does not suit the duty (e.g. ordinary cartridges on oily dust), replace it with the right type.
04
About energy savings
Savings depend on the existing system and the measures taken. We estimate from baseline data at proposal stage and check afterwards at the same points and conditions, so the results are measured, not assumed.