SVT Venturi Wet Scrubber

A venturi wet scrubber: dusty gas mixes with water at high speed in the venturi throat, the water carries the dust away and a scraper removes the sludge. SVT-1 to SVT-10, 2,000–16,000 m³/h. For aluminium and magnesium dust, sticky or damp dust, and fume that needs cooling.

SVT series product image
SVT Venturi Wet Scrubber

Reference configuration: SVT-1

Rated treatment airflow
2000 m³/h
Reserved system negative pressure
800 Pa
Fan power
4 kW
Recirculating water capacity
1300 L
Inlet diameter
190 mm
Operating weight
2950 kg

Values above apply to SVT-1; compare other models below.

Where it fits

Aluminium, magnesium, titanium grinding
Avoids the fire risk of dry collection.
Sticky or damp dust
Wet processing of glass, ceramics and stone.
Quench and hot-forging smoke
Scrubbed and cooled together.

Features

High-efficiency dust removal
The venturi throat intensifies gas/liquid contact for particle capture at the design duty.
Economical to run
Washable components and the water circuit support operating and maintenance planning.
Flexible modular configuration
Flow, dust, temperature and available space determine configuration.

How it works

SVT structure: side inlet with a water-fed venturi throat, mist eliminator in the upper body, top-mounted fan; base water tank, recirculation pump, float make-up, and a scraper lifting sludge into a cart.
SVT venturi wet scrubber: structure and principle

SVT venturi wet scrubber: structure and principle.

Component reading

  • Dusty gas enters the side inlet and mixes at high speed with pumped water in the venturi throat; the dust is wetted.
  • Dirty droplets fall back to the base tank and the pump reuses the water.
  • The gas rises through the body; the mist eliminator removes fine droplets and the top-mounted fan discharges it.
  • A float tops up the water; sludge settles and the scraper lifts it into the cart continuously.
1 Acceleration
Dusty gas accelerates through the venturi throat.
2 Mixing
It meets water at high speed and the dust is wetted.
3 Separation
Gas and liquid separate, a demister removes droplets, and clean air leaves.
4 Sludge removal
Sludge settles and the scraper removes it.

Maintenance and wear parts

Each shift, check water level, pump, demister and blowdown.

Clean the throat, separator and sludge areas regularly, and set make-up, blowdown and desludging to the load.

Wear parts: pump parts, spray and distribution parts, seals, demister, and worn contact surfaces.

FAQ

Which dusts suit wet collection first?
Combustible metal dust such as aluminium and magnesium, sticky or damp dust, and fume that needs cooling.
Does water remove all risk?
No. Aluminium and magnesium sludge releases hydrogen, so ventilate the tank and remove sludge promptly.
What does the site need?
Power, make-up water, drainage and a place for sludge; frost protection outdoors in winter.

SVT / SPECIFICATIONS

Specifications

Discuss SVT configurations

Compare models by filter media.

Scroll the table horizontally to compare models; on a phone, open each configuration card.

SVTmodel comparison
Parameter / conditionSVT-1SVT-2SVT-3SVT-4SVT-5SVT-6SVT-7SVT-8SVT-9SVT-10
Rated treatment airflowm³/h2000350045005500650080009000110001350016000
Reserved system negative pressurePa80080080080080010001000100010001000
Fan powerkW45.57.511111518.5222230
Water pump powerkW0.751.51.52.22.22.22.23.755.55.5
Sludge scraper powerkW0.180.180.180.180.180.180.180.180.180.18
Recirculating water capacityL1300130014001700210021002250282038204000
Inlet diametermm190250280320340380400450480530
Scrubber widthmm1100110011501200145014501450160018002000
Sludge scraper heightmm1850185018301900206020602060221024252425
Scrubber body heightmm2458260826083208320832083208360838104010
Fan heightmm68473876194294294298395811061136
Overall heightmm3142334633694150415041504191456649165146
Inlet heightmm1951203620572302249225102550269229803135
Outlet heightmm2702284928493489348934893489388641414338
Inlet centre distancemm7939119721084125413631433145416231845
Outlet centre distancemm450500550600655700750800865965
Overall scrubber lengthmm3000300031003200360036003600391646704800
Outlet widthmm406406406506506506506506606606
Outlet section heightmm331331331406406406406406506506
Operating weightkg2950310034003950450046504880558073507950
SVT-1
Rated treatment airflowm³/h
2000
Reserved system negative pressurePa
800
Fan powerkW
4
Water pump powerkW
0.75
Sludge scraper powerkW
0.18
Recirculating water capacityL
1300
Inlet diametermm
190
Scrubber widthmm
1100
Sludge scraper heightmm
1850
Scrubber body heightmm
2458
Fan heightmm
684
Overall heightmm
3142
Inlet heightmm
1951
Outlet heightmm
2702
Inlet centre distancemm
793
Outlet centre distancemm
450
Overall scrubber lengthmm
3000
Outlet widthmm
406
Outlet section heightmm
331
Operating weightkg
2950
Enquire about this model
SVT-2
Rated treatment airflowm³/h
3500
Reserved system negative pressurePa
800
Fan powerkW
5.5
Water pump powerkW
1.5
Sludge scraper powerkW
0.18
Recirculating water capacityL
1300
Inlet diametermm
250
Scrubber widthmm
1100
Sludge scraper heightmm
1850
Scrubber body heightmm
2608
Fan heightmm
738
Overall heightmm
3346
Inlet heightmm
2036
Outlet heightmm
2849
Inlet centre distancemm
911
Outlet centre distancemm
500
Overall scrubber lengthmm
3000
Outlet widthmm
406
Outlet section heightmm
331
Operating weightkg
3100
Enquire about this model
SVT-3
Rated treatment airflowm³/h
4500
Reserved system negative pressurePa
800
Fan powerkW
7.5
Water pump powerkW
1.5
Sludge scraper powerkW
0.18
Recirculating water capacityL
1400
Inlet diametermm
280
Scrubber widthmm
1150
Sludge scraper heightmm
1830
Scrubber body heightmm
2608
Fan heightmm
761
Overall heightmm
3369
Inlet heightmm
2057
Outlet heightmm
2849
Inlet centre distancemm
972
Outlet centre distancemm
550
Overall scrubber lengthmm
3100
Outlet widthmm
406
Outlet section heightmm
331
Operating weightkg
3400
Enquire about this model
SVT-4
Rated treatment airflowm³/h
5500
Reserved system negative pressurePa
800
Fan powerkW
11
Water pump powerkW
2.2
Sludge scraper powerkW
0.18
Recirculating water capacityL
1700
Inlet diametermm
320
Scrubber widthmm
1200
Sludge scraper heightmm
1900
Scrubber body heightmm
3208
Fan heightmm
942
Overall heightmm
4150
Inlet heightmm
2302
Outlet heightmm
3489
Inlet centre distancemm
1084
Outlet centre distancemm
600
Overall scrubber lengthmm
3200
Outlet widthmm
506
Outlet section heightmm
406
Operating weightkg
3950
Enquire about this model
SVT-5
Rated treatment airflowm³/h
6500
Reserved system negative pressurePa
800
Fan powerkW
11
Water pump powerkW
2.2
Sludge scraper powerkW
0.18
Recirculating water capacityL
2100
Inlet diametermm
340
Scrubber widthmm
1450
Sludge scraper heightmm
2060
Scrubber body heightmm
3208
Fan heightmm
942
Overall heightmm
4150
Inlet heightmm
2492
Outlet heightmm
3489
Inlet centre distancemm
1254
Outlet centre distancemm
655
Overall scrubber lengthmm
3600
Outlet widthmm
506
Outlet section heightmm
406
Operating weightkg
4500
Enquire about this model
SVT-6
Rated treatment airflowm³/h
8000
Reserved system negative pressurePa
1000
Fan powerkW
15
Water pump powerkW
2.2
Sludge scraper powerkW
0.18
Recirculating water capacityL
2100
Inlet diametermm
380
Scrubber widthmm
1450
Sludge scraper heightmm
2060
Scrubber body heightmm
3208
Fan heightmm
942
Overall heightmm
4150
Inlet heightmm
2510
Outlet heightmm
3489
Inlet centre distancemm
1363
Outlet centre distancemm
700
Overall scrubber lengthmm
3600
Outlet widthmm
506
Outlet section heightmm
406
Operating weightkg
4650
Enquire about this model
SVT-7
Rated treatment airflowm³/h
9000
Reserved system negative pressurePa
1000
Fan powerkW
18.5
Water pump powerkW
2.2
Sludge scraper powerkW
0.18
Recirculating water capacityL
2250
Inlet diametermm
400
Scrubber widthmm
1450
Sludge scraper heightmm
2060
Scrubber body heightmm
3208
Fan heightmm
983
Overall heightmm
4191
Inlet heightmm
2550
Outlet heightmm
3489
Inlet centre distancemm
1433
Outlet centre distancemm
750
Overall scrubber lengthmm
3600
Outlet widthmm
506
Outlet section heightmm
406
Operating weightkg
4880
Enquire about this model
SVT-8
Rated treatment airflowm³/h
11000
Reserved system negative pressurePa
1000
Fan powerkW
22
Water pump powerkW
3.75
Sludge scraper powerkW
0.18
Recirculating water capacityL
2820
Inlet diametermm
450
Scrubber widthmm
1600
Sludge scraper heightmm
2210
Scrubber body heightmm
3608
Fan heightmm
958
Overall heightmm
4566
Inlet heightmm
2692
Outlet heightmm
3886
Inlet centre distancemm
1454
Outlet centre distancemm
800
Overall scrubber lengthmm
3916
Outlet widthmm
506
Outlet section heightmm
406
Operating weightkg
5580
Enquire about this model
SVT-9
Rated treatment airflowm³/h
13500
Reserved system negative pressurePa
1000
Fan powerkW
22
Water pump powerkW
5.5
Sludge scraper powerkW
0.18
Recirculating water capacityL
3820
Inlet diametermm
480
Scrubber widthmm
1800
Sludge scraper heightmm
2425
Scrubber body heightmm
3810
Fan heightmm
1106
Overall heightmm
4916
Inlet heightmm
2980
Outlet heightmm
4141
Inlet centre distancemm
1623
Outlet centre distancemm
865
Overall scrubber lengthmm
4670
Outlet widthmm
606
Outlet section heightmm
506
Operating weightkg
7350
Enquire about this model
SVT-10
Rated treatment airflowm³/h
16000
Reserved system negative pressurePa
1000
Fan powerkW
30
Water pump powerkW
5.5
Sludge scraper powerkW
0.18
Recirculating water capacityL
4000
Inlet diametermm
530
Scrubber widthmm
2000
Sludge scraper heightmm
2425
Scrubber body heightmm
4010
Fan heightmm
1136
Overall heightmm
5146
Inlet heightmm
3135
Outlet heightmm
4338
Inlet centre distancemm
1845
Outlet centre distancemm
965
Overall scrubber lengthmm
4800
Outlet widthmm
606
Outlet section heightmm
506
Operating weightkg
7950
Enquire about this model