The Measure of Clean Air.

SVB-T / SCALES

SVB-T Integrated High-Vacuum Bag Dust Collector

An integrated high-vacuum bag unit: suction, filtration, cleaning and collection in one cabinet with VFD constant-pressure control. SVB-T-7.5 and SVB-T-18.5, 500–1,000 m³/h, with optional H13 or H14 final stage and explosion protection.

SVB-T series product image
SVB-T Integrated High-Vacuum Bag Dust Collector

Where it fits

A few tools or one or two machines
Local extraction without a central network.
Automotive and composite sanding
Body sanding and rework, composite trimming and sanding.
Batteries and electronics
Electrode and pack finishing, machine-port extraction.

Features

Stable high-vacuum operation
High-vacuum duty is organized for long connections and multiple points.
Constant-pressure VFD control
VFD control with pressure feedback adjusts operation to the duty.
Automatic pulse cleaning
Automatic pulse cleaning supports filter condition.
Safety options
Special protective options include spark detection, venting and interlocks following the application assessment.

How it works

1 Suction
High suction at the tool through the hose.
2 Constant pressure
Pressure feedback and VFD keep suction steady as tools come and go.
3 Filtration and cleaning
Bag filtration with automatic reverse cleaning; optional H13 or H14 stage.
4 Collection
Dust goes to the container.

Maintenance and wear parts

Check bags and seals, pulse air lines, pressure-feedback points and the container.

If suction fluctuates, first check how many tools are in use and the valves, then bags and hoses.

Replace the HEPA stage on recorded pressure drop.

FAQ

How does it differ from SVB?
SVB-T is an integrated unit for a few nearby tools; SVB is modular for many points across a hall.
What does the VFD do?
It adjusts speed to the tools in use, keeping suction steady and saving power.
Combustible dust?
Explosion protection, spark detection, venting and interlocks are available, configured from dust test results.

SVB-T / SPECIFICATIONS

Specifications

Discuss SVB-T configurations

Airflow is calculated for the listed media and filtration velocity; system airflow is set by the workstations, hoods and ductwork.

Scroll the table horizontally to compare models; on a phone, open each configuration card.

SVB-Tmodel comparison
Parameter / conditionSVB-T-7.5SVB-T-18.5
Overall dimensionsmm1500×750×20601800×1100×2060
Rated airflowm³/h5001000
PowerkW7.518.5
Total filtration aream²4.28.0
Filter element count1834
Maximum working negative pressurekPa-25-25
Power supplyAC 380 V / 3 Ph / 50 HzAC 380 V / 3 Ph / 50 Hz
Dust collection capacityL4040
SVB-T-7.5
Overall dimensionsmm
1500×750×2060
Rated airflowm³/h
500
PowerkW
7.5
Total filtration aream²
4.2
Filter element count
18
Maximum working negative pressurekPa
-25
Power supply
AC 380 V / 3 Ph / 50 Hz
Dust collection capacityL
40
Enquire about this model
SVB-T-18.5
Overall dimensionsmm
1800×1100×2060
Rated airflowm³/h
1000
PowerkW
18.5
Total filtration aream²
8.0
Filter element count
34
Maximum working negative pressurekPa
-25
Power supply
AC 380 V / 3 Ph / 50 Hz
Dust collection capacityL
40
Enquire about this model

PROCESS & INDUSTRY GUIDANCE

Industries and processes

Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.