SOM / SCALES
SOM Multi-Stage Oil Mist Collector
A combined mist collector with multi-stage pre-separation and a final filter: large droplets and particles first, then fine mist. 1,200 m³/h per unit.
Metric
Conversion basis
Airflow: m³/h × 0.5886 = CFM. Pressure: Pa ÷ 249.09 = in.w.g. (4°C water column). Length: mm ÷ 25.4 = in. Imperial values are rounded to 2 decimal places. Other values are shown in their original units. Entries marked “not converted” retain metric units.

Where it fits
- Heavy emulsion mist
- Machines with high-pressure, high-flow coolant.
- Mist with particles
- Grinding and honing, with metal fines in the mist.
- Low noise
- Near the operator area.
Features
- Multi-stage filtration
- Pre-separation and final filtration progressively reduce loading.
- Pre-separation of mist and solids
- Coarse droplets and solids are removed before later stages.
- High-efficiency final stage
- A final filter addresses remaining fine aerosol.
- Low noise, easy service
- The fan and staged arrangement support noise and maintenance planning.
How it works
- 1 Pre-separation
- Several stages remove large droplets and particles.
- 2 Final filtration
- High-efficiency media captures fine mist.
- 3 Drainage
- Oil from each stage drains out.
Maintenance and wear parts
Maintain stage by stage: oil and solids at the front, resistance and airflow at each stage, seals and containers.
Dry washable parts fully before refitting; replace others as specified.
Wear parts: media, seals, drain connections.
FAQ
- What load does it suit?
- High concentration, large droplets and particles.
- Why several stages?
- The front stages remove large droplets so the final media does not blind and lasts longer.
- Can recovered oil be reused?
- Only if it is clean and matches the machine's fluid.
SOM / SPECIFICATIONS
Specifications
Airflow is calculated for the listed media and filtration velocity; system airflow is set by the workstations, hoods and ductwork.
- Rated airflowm³/h
- 1200
- Fan powerkW
- 1.1
- NoisedB(A)
- 72 dB(A)
- Effective filtration aream²
- 4.5
- Overall dimensionsmm
- 405×405×1040
This series is supplied as a single configuration without sub-models; describe your application when enquiring.
PROCESS & INDUSTRY GUIDANCE
Industries and processes
Explore the release points, capture arrangements and maintenance tasks in the relevant process or production stage.