Managing Water and Sludge in Wet Dust Collection Systems
A wet collector runs on water, so water level, quality and sludge need daily attention. The system stays stable when make-up water equals what is drained, evaporated and carried away.
Request a Technical AssessmentWater balance
In steady running, make-up = blowdown + evaporation + carry-over. For example, 100 L/h make-up against 60 L/h blowdown, 30 L/h evaporation and 10 L/h carry-over gives 100 − 60 − 30 − 10 = 0, so the level stays constant. A level that keeps falling or rising points to leaks, the make-up valve or the demister.
Daily management
- Water level: keep within range; the low-level alarm must work.
- Water quality: too much sludge blocks nozzles and lowers efficiency, so blow down and refresh on schedule.
- Sludge: SCALES SVT has a scraper; dispose of collected sludge to local rules.
- Demister: water at the outlet means a blocked demister or too much airflow.
Special cases
- Aluminium and magnesium dust: sludge releases hydrogen; ventilate the tank and never store sludge sealed.
- Winter: protect outdoor equipment and pipes from freezing.
- Corrosive components: choose corrosion-resistant housing, pump and pipes.