Pulse-jet cleaning knocks dust off the media with short bursts of compressed air. Air consumption = air per pulse × number of pulses; the supply must be dry, oil-free and steady.
Request a Technical Assessment
A worked example
At 12 L per pulse and 15 pulses per minute for the whole unit, average consumption = 12 × 15 ÷ 1,000 = 0.18 m³/min, or 10.8 m³/h, about 86.4 m³ over 8 hours. Air per pulse comes from the equipment data or measurement.
Average consumption is not the instantaneous demand: each pulse draws a high flow, so the receiver and piping must refill quickly.
Air supply
- Steady pressure: SCALES SCU pulse valves work from 0.2 to 0.6 MPa.
- Dry and oil-free: water and oil damage valve diaphragms and blind the media. Fit a dryer and filter at the supply.
- Drain condensate from the receiver and lines weekly.
Saving compressed air
Clean on pressure drop: pulse only when it reaches the set point, which saves air and media wear compared with timed cleaning. Run a final clean after shutdown to clear the dust before stopping.