The Measure of Clean Air.

TECHNICAL KNOWLEDGE

Oil Drainage and Buildup Management in Oil Mist Collectors

Oil captured by a mist collector must drain freely. If it does not, oil builds up in the unit and ducts, causing leaks, lower efficiency and even fire.

Request a Technical Assessment
Air passing through a collection stage from left to right while droplets drain down through a separate outlet into a vessel.
Air continues through the collection stage while liquid follows a separate downward path. Open full diagram ↗

Where the oil goes

  • In the unit: oil from each stage collects in the drain pan and leaves through the drain port.
  • In ducts: slope horizontal runs towards the unit and fit drains at low points.
  • Outlet: pipe the drain to a container, or back to the machine sump through a strainer.

Use drained volume as a check

Record the oil drained per shift under the same machining conditions. If one day yields 12 L in 8 hours (1.5 L/h) and another day only 6 L (0.75 L/h) under the same conditions, check for a blocked drain, oil building up inside, or a change in machining.

Routine care

  • Daily: check the drain is dripping and the container is not full.
  • Weekly: check pre-filters and remove oil.
  • Fit a trap or check valve on the drain so suction does not draw air in and stop the oil draining.
  • Reuse recovered oil only if it is clean and matches the machine's fluid.