TECHNICAL KNOWLEDGE
Cooling and Filtering Fumes from Foundry Melting Operations
Furnace fume is hot and surges at charging and tapping. Cool it to what the bags can take before the baghouse; cooler gas has less volume, so the collector can also be smaller.
Request a Technical Assessment
How to cool the fume
- Dilution with ambient air: simple, but increases airflow and collector size.
- Air- or water-cooled ducts or coolers: no extra airflow, but take space.
- Spray cooling: fast, but avoid condensation and blinding the bags.
- Fit temperature monitoring and over-temperature protection after cooling, opening a bleed-air damper or alarming when it runs hot.
Filtration
After cooling, size the bag area from the actual airflow and filtration velocity: A = Q ÷ (60 × v). For example, 18,000 m³/h at 0.80 m/min needs 18,000 ÷ (60 × 0.80) = 375 m².
SMB reverse-air trolley baghouses suit hot gas from aluminium and foundry work and clean without stopping; SIB suits high airflow; SMC suits limited headroom.
Furnace hoods
Hoods swing clear for charging and tapping and cover the furnace while melting; side hoods sit close to the mouth and clear of the crane path. The furnace mouth sees splash and radiant heat, so operator safety decides hood position.