Filtration Velocity and Filter Area
Filter area = airflow ÷ (60 × filtration velocity). A lower velocity eases the load on the media and extends its life but needs a larger collector. Choose the velocity for the dust and media, then calculate the area.
Request a Technical Assessment
A worked example
At 7,200 m³/h actual inlet airflow and 0.80 m/min, A = 7,200 ÷ (60 × 0.80) = 150 m². At 1.00 m/min, A = 7,200 ÷ 60 = 120 m².
Area falls during maintenance
If the 150 m² comes from three 50 m² compartments and one is taken offline, only 100 m² remains and filtration velocity becomes 7,200 ÷ (60 × 100) = 1.20 m/min. Check that this state is acceptable when selecting.
Choosing filtration velocity
- Fine fume from welding and laser cutting: use the lower end. SCALES lists SCU airflow for 0.85–1.2 m/min.
- Heavy, sticky or damp dust: lower values, or use a baghouse or wet collector.
- Use the actual airflow at the collector inlet; correct hot gas to its actual temperature.